Oxidative stress is hypothesized to play an important role in a variety of chronic diseases, but the short-term and long-term stability of measurements of biomarkers related to oxidative stress remains unclear. The objective of this study was to evaluate the stability of measurements of malondialdehyde (MDA), F2-isoprostanes, and fluorescent oxidation products in blood stored on ice within 36 hours until processing. Whole blood samples from six healthy women were processed at 0, 24, and 36 hours after being stored on ice. MDA was measured by the thiobarbituric acid–reactive substances assay with high-pressure liquid chromatography. F2-isoprostanes were measured by gas chromatography/mass spectrometry. The fluorescent oxidation products were measured by spectrofluorometry. Measurements of fluorescent oxidation products were very stable up to 36 hours. Intraclass correlation coefficients (ICC) were >0.95 for each time interval (0 to 24 and 0 to 36 hours). Measurements of MDA were the least stable. The median increased significantly from 0 to 24 hours and from 0 to 36 hours. The ICC for MDA for each time interval (0 to 24 and 0 to 36 hours) was <0.1. Finally, the median of F2-isoprostane measurements at each time point also increased significantly. ICCs were 0.45 for 0 to 24 hours and 0.09 for 0 to 36 hours. We conclude that measurements of fluorescent oxidation products in blood remain stable for up to 36 hours and may be used in large prospective epidemiologic studies of chronic diseases.

Many biomarkers have been developed to evaluate oxidative stress. Malondialdehyde (MDA) and F2-isoprostanes are two markers widely used. Increased plasma MDA levels (1-4) and F2-isoprostanes (5-9) have been found in a variety of disease conditions and among smokers. Recently, Mezzetti et al. (10) have shown that fluorescent products of lipid peroxidation (FLIP), many of which are conjugated Schiff bases (11), predict the risk of cardiovascular events in a group of healthy, elderly subjects. Those with FLIPs in the highest quartile had a risk seven times greater than those with FLIPs in the lowest quartile. In addition, these Schiff base products and their derived products—advanced glycation end products (12)—have been implicated in several diseases such as Alzheimer's disease (13, 14), cancer (15), nondiabetic nephropathy (16), and diabetes complications (17). Although markers of fluorescent oxidation products have not been widely used, this assay is relatively simple and has potential to be used in epidemiologic studies.

The influence of the time to processing on the stability of biomarkers needs to be examined before applying them to epidemiologic studies. In large cohort studies such as the Nurses' Health Study and the Health Professionals Follow-up Study, blood samples are collected, placed on ice, and shipped to the central laboratory overnight or the next day. The time frame for processing the samples after their placement on ice ranges from 0 to 36 hours. To our knowledge, the stability of measurements of MDA, F2-isoprostanes, and fluorescent oxidation products in whole blood samples stored on ice has not been examined previously.

Blood Collection and Processing

Blood samples were collected from six healthy women ages 25 to 45 years. The project was approved by the Harvard School of Public Health Institutional Review Board, and all volunteers gave written informed consent. For each subject, blood was collected into three 10 mL Vacutainer (sodium heparin) tubes, which were placed immediately on ice. These three tubes were processed at 0, 24, and 36 hours. Samples processed at 24 and 36 hours were first placed in a Styrofoam container with ice packs, simulating conditions of overnight and next-day mail service in our main cohort study. At each time point, whole blood samples were centrifuged and plasma samples were aliquoted for storage in liquid nitrogen (−140°C). Each sample was aliquoted in duplicate tubes, assigned a different identification number, and randomly placed in the analysis batch with respect to the three different processing time periods. All assays were conducted without knowledge of the status of each sample.

Assays

Measurement of MDA via the thiobarbituric acid (TBA)–reactive substances assay was carried out with high-pressure liquid chromatography, which is considered to be relatively sensitive and more specific than the TBA assay by spectrofluorometry (18). The high-pressure liquid chromatography model was Shimadzu SIL-10A with fluorescent detector (Shimadzu RF-10A) with 532/553 nm wavelength (excitation/emission). We used the procedures described by Young and Trimble (19). The only modification was our use of a different column. The procedures are described briefly below. There were two steps in this assay: derivatization and neutralization. After the neutralization, a 40 μL suspension was injected (automated injector with 50 μL sample loop) onto a C18 column (ODS Ultrasphere, 5 μm, 150 × 4.6 mm; Beckman Coulter, San Diego, CA) using a mobile phase that contained 50% methanol/50% phosphate buffer at pH 6.5 at a flow rate of 0.8 mL/min. MDA (Sigma-Aldrich, St. Louis, MO) was used as an external standard. MDA standards (0, 0.24, 0.48, 1.2, 2.4, and 4.8 μmol/L) were prepared with 1,1,3,3-tetramethoxypropane, which yields equivalent amounts of MDA under the conditions of the reaction. The correlation for the linearity of the standard curve was 0.99. We also have set up a standard curve by spiking the above MDA standards with plasma; the recovery of MDA from spiked plasma ranged from 95% to 100%. Intraassay and interassay coefficients of variation were <15%.

F2-isoprostanes were measured by gas chromatography/mass spectrometry as described previously (20-22). Intraassay and interassay coefficients of variation averaged 9%. This assay is well established and used in several studies (5-9, 21). As described in Morrow and Roberts (22), the accuracy of this assay is 96%, which is determined by quantification of an added known amount of the F2-isoprostanes to plasma.

The procedures for measuring fluorescent oxidation products were modified from the method of Shimasaki (23). In brief, 0.2 mL of plasma samples was mixed with 1 mL of ethanol/ether (3:1 v/v) in borosilicate glass tubes (1495935c, Fisher, Hanover Park, IL) and vigorously mixed on a vortex mixer. The mixed solution was centrifuged for 10 minutes at 3000 rpm, and 1 mL of supernatant was added to cuvettes for spectrofluorometric readings. The fluorescence can be determined as relative fluorescence intensity units per milliliter of plasma at 360/430 nm wavelength (excitation/emission) by a spectrofluorometer (Shimadzu RF-5301 PC). Quinine sulfate in diluted 0.1 N H2SO4 was used for calibration. To verify whether this assay can reflect the change of oxidative insult, we did the following experiments. Pooled plasma samples were diluted (∼150-fold, 0.5 mg/mL protein) and oxidized with 5 μmol/L CuSO4 at 37°C. An aliquot of plasma was removed after 12, 24, 36, 48, 72, 96, 120, 144, 168, 192, and 216 hours. EDTA (1.5 mg/mL) was added immediately to halt the oxidation reactions. Aliquots at each time point were measured by this assay. We plotted a curve based on the results. The fluorescent intensity range of our sample was well below the range of this curve. Accuracy of analysis was also achieved by inclusion low, medium, and high quality controls; the intraassay and interassay coefficients of variation were <10%. The quality controls were obtained from the serially diluted pooled plasma samples oxidized for 192 hours (as described above).

Statistical Analysis

To assess within-subject coefficients of variation, each sample was aliquoted in duplicate tubes for each subject at each time point and randomly placed in the analysis batch with a dummy ID. However, in large epidemiologic studies where plasma is limited, it is not always possible to conduct two measurements on the same person. Therefore, to be conservative, we only use the first observation for primary analysis (presented in Table 1). However, we also conducted a secondary analysis using the means of the duplicates for each subject to illustrate the marginal increase in accuracy with duplicate measurements (Table 1). If a variable was not normally distributed, log-transformed data were used for statistical analysis. A paired t test was used to compare means between different time points within an individual. Intraclass correlation coefficients (ICC) were calculated by ANOVA to determine the stability over time within an individual (24). All analyses were conducted in SAS 6.12. By definition of the ICC (between-person variance divided by the sum of the between-person and within-person variances), if a biomarker is not stable over time, the within-person variance will increase and the ICC will decrease. Therefore, we also calculated the Pearson (for normally distributed data) and Spearman (for nonnormally distributed data) correlations because they are sensitive only to relative stability between subjects.

Table 1.

Stability of whole blood samples on ice from 0 to 36 hours before processing (n = 6)

Median (Interquartile Range)
P for Paired t Test
ICC
0 Hours24 Hours36 Hours0-24 Hours0-36 Hours0-24 Hours0-36 Hours
Analysis based on single measurement per subject        
MDA (μmol/L) via TBA assay 1.94 (1.59-2.50) 2.92 (2.87-3.33) 3.85 (3.03-4.70) 0.03 0.001 −0.09 −0.11 
Esterified F2-isoprostanes* (pg/mL) 46.0 (35.0-69.0) 83.0 (76.0-95.0) 129.5 (84.0-183.0) 0.05 0.01 0.45 0.09 
Fluorescent assay (fluorescent intensity/mL) 164 (127-190) 163 (134-200) 163 (134-194) 0.3 0.5 0.96 0.98 
Analysis based on duplicate measures per subject        
MDA (μmol/L) via TBA assay 1.97 (1.53-2.43) 3.21 (2.91-3.54) 3.71 (3.32-4.6) 0.01 0.003 0.16 0.02 
Esterified F2-isoprostanes (pg/mL) 55.3 (47.5-76.5) 73.5 (69.0-88.5) 101.3 (68.3-123.5) 0.04 0.02 0.74 0.51 
Fluorescent assay (fluorescent intensity/mL) 177 (129-208) 170 (145-202) 166 (142-198) 0.7 0.3 0.97 0.97 
Median (Interquartile Range)
P for Paired t Test
ICC
0 Hours24 Hours36 Hours0-24 Hours0-36 Hours0-24 Hours0-36 Hours
Analysis based on single measurement per subject        
MDA (μmol/L) via TBA assay 1.94 (1.59-2.50) 2.92 (2.87-3.33) 3.85 (3.03-4.70) 0.03 0.001 −0.09 −0.11 
Esterified F2-isoprostanes* (pg/mL) 46.0 (35.0-69.0) 83.0 (76.0-95.0) 129.5 (84.0-183.0) 0.05 0.01 0.45 0.09 
Fluorescent assay (fluorescent intensity/mL) 164 (127-190) 163 (134-200) 163 (134-194) 0.3 0.5 0.96 0.98 
Analysis based on duplicate measures per subject        
MDA (μmol/L) via TBA assay 1.97 (1.53-2.43) 3.21 (2.91-3.54) 3.71 (3.32-4.6) 0.01 0.003 0.16 0.02 
Esterified F2-isoprostanes (pg/mL) 55.3 (47.5-76.5) 73.5 (69.0-88.5) 101.3 (68.3-123.5) 0.04 0.02 0.74 0.51 
Fluorescent assay (fluorescent intensity/mL) 177 (129-208) 170 (145-202) 166 (142-198) 0.7 0.3 0.97 0.97 
*

Data were log transformed.

Geometric means are presented.

The coefficients of variation were 8.32%, 15.8%, and 10.2% for the measurement of fluorescent oxidation products, MDA, and F2-isoprostanes. These coefficients of variation are all in a reasonable and acceptable range. Table 1 shows the median value and stability of measurements of the three oxidation markers, MDA measured by TBA, F2-isoprostanes by gas chromatography/mass spectrometry, and fluorescence intensity of oxidation products at 0, 24, and 36 hours. In our primary analysis based on single measurement, concentrations of MDA increased significantly from 0 to 24 hours and from 0 to 36 hours. Esterified F2-isoprostanes also increased significantly from 0 to 36 hours. Fluorescence intensity of fluorescent oxidation products remained unchanged from 0 to 36 hours. As shown in Table 1, the ICCs of the TBA assay were poor for 0 to 24 and 0 to 36 hours. Esterified F2-isoprostane had better reproducibility for 0 to 24 hours (ICC = 0.45) and for 0 to 36 hours (ICC = 0.09) than MDA. The ICCs for fluorescent oxidation products were excellent (0.96 and 0.98 for 0 to 24 and 0 to 36 hours, respectively). Results from Pearson or Spearman correlation also confirmed that fluorescent oxidation products were the most stable. The correlations for fluorescent oxidation products were 0.99 and 0.98 for 0 to 24 and 0 to 36 hours, respectively (P's < 0.05). The correlations for MDA were 0.39 (P = 0.4) and 0.89 (P = 0.02) for 0 to 24 and 0 to 36 hours, respectively. The correlations for F2-isoprostanes were 0.89 (P = 0.02) and 0.2 (P = 0.7) for 0 to 24 and 0 to 36 hours, respectively.

In addition, we reanalyzed the data using the means of the duplicate assessments for each subject (Table 1). The results were similar, although the ICCs improved modestly for F2-isoprostanes (0.74 and 0.51 for 0 to 24 and 0 to 36 hours, respectively).

In this pilot study, we found that measurements of fluorescent oxidation products by FLIP assay in blood samples held on ice for 36 hours until processing remained essentially unchanged. In contrast, measurements of MDA significantly increased from 0 to 24 hours and from 0 to 36 hours. F2-isoprostane measurements increased in the same direction as MDA, although the magnitude was less. The reason for the increases in the levels of MDA and F2-isoprostanes detected in blood during storage is undoubtedly due to autoxidation of plasma lipids with artifactual generation of MDA and isoprostanes. Why such increases were not observed with products measured by the FLIP assay is not clear.

Although the sample size was small (n = 6) in this study, the results of FLIP assays were substantially better than those for MDA or F2-isoprostanes. The coefficients of variation were the lowest for FLIP assay (<10%); the percentage of differences in the median for the time intervals (0 to 24 and 0 to 36 hours) was <6%, and both ICC and Pearson correlation for each time interval were excellent. The results for MDA suggest that this assay cannot be used in epidemiologic studies when samples are not processed immediately. Not only did the median increase from 0 to 24 hours and from 0 to 36 hours, but the ICCs were also poor (<0.1). An ICC of <0.1 indicates that >90% of the variation in concentration in the 36-hour samples are attributable to the delay in processing.

For F2-isoprostanes, both ICCs and Spearman correlations were modest or good for 0 to 24 hours but not for 0 to 36 hours. Whether this marker is potentially useful in large epidemiologic studies (with a single sample) is unclear because of the small sample size. For studies with duplicate samples and a processing time of whole blood within 24 hours, F2-isoprostanes may still be acceptable. F2-isoprostanes are considered to be one of the best lipid peroxidation markers; thus, further work is warranted to explore the reproducibility and validity of this marker with a larger sample size.

The use of different anticoagulants for blood collection may affect the interpretation of our results. For the TBA assay and FLIP assay, we found little differences between fresh EDTA and heparin blood samples. However, we have not compared these two types of blood collection for the three measurements after whole blood has been kept on ice for up to 36 hours. Because EDTA is a metal chelator, it theoretically should prevent oxidation. Kontush and Beisiegel (25) showed that plasma samples prepared with different anticoagulants exhibit different oxidation kinetics. The oxidation rate of EDTA plasma is lower than that of heparin plasma. However, Pischon et al. (26) found that, after storage of blood on ice for 36 hours, the levels of adiponectin significantly increased in blood collected with EDTA but not in blood collected with heparin. His finding raises concerns about EDTA collection versus heparin collection, although adiponectin is an adipose-derived hormone, not an oxidation marker.

FLIPs may be an insufficient description of these oxidation products. In general, they are carbonyl compounds—aldehydes cross-linked with amino acids (11, 12). Aldehydes can derive from lipids, carbohydrates, amino acids, and DNA (11, 12, 27). Thus, fluorescent oxidation products are markers of overall lipid, protein, carbohydrate, and DNA oxidation. Although the FLIP assay seems to have potential for application in epidemiologic studies, the stability of measurements using the FLIP assay in long-term storage, its reproducibility over time within persons, and its determinants also need to be tested before this assay can be considered useful in epidemiologic studies.

Grant support: NIH grants CA49449, 5 P01 CA 87969, 5 R01 DK58845, GM42056, and DK26657 and Colorectal Cancer Research Fund.

The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

1
Meraji S, Abuja PM, Hayn M, et al. Relationship between classic risk factors, plasma antioxidants and indicators of oxidant stress in angina pectoris (AP) in Tehran.
Atherosclerosis
2000
;
150
:
403
-12.
2
Singh V, Ghalaut PS, Kharb S, Singh GP. Plasma concentrations of lipid peroxidation products in children with acute leukemia.
Indian J Med Sci
2001
;
55
:
215
-7.
3
Skrzydlewska E, Stankiewicz A, Sulkowska M, Sulkowski S, Kasacka I. Antioxidant status and lipid peroxidation in colorectal cancer.
J Toxicol Environ Health A
2001
;
64
:
213
-22.
4
Shimizu I, Inoue H, Yano M, et al. Estrogen receptor levels and lipid peroxidation in hepatocellular carcinoma with hepatitis C virus infection.
Liver
2001
;
21
:
342
-9.
5
Belton O, Byrne D, Kearney D, Leahy A, Fitzgerald DJ. Cyclooxygenase-1 and -2-dependent prostacyclin formation in patients with atherosclerosis.
Circulation
2000
;
102
:
840
-5.
6
Cracowski JL, Tremel F, Marpeau C, et al. Increased formation of F[2]-isoprostanes in patients with severe heart failure.
Heart
2000
;
84
:
439
-40.
7
Wood LG, Fitzgerald DA, Gibson PG, Cooper DM, Garg ML. Lipid peroxidation as determined by plasma isoprostanes is related to disease severity in mild asthma.
Lipids
2000
;
35
:
967
-74.
8
Pratico D, Clark CM, Lee VM, Trojanowski JQ, Rokach J, FitzGerald GA. Increased 8,12-iso-iPF2α-VI in Alzheimer's disease: correlation of a noninvasive index of lipid peroxidation with disease severity.
Ann Neurol
2000
;
48
:
809
-12.
9
Morrow JD, Frei B, Longmire AW, et al. Increase in circulating products of 10.lipid peroxidation (F2-isoprostanes) in smokers. Smoking as a cause of oxidative damage.
N Engl J Med
1995
;
332
:
1198
-203.
10
Mezzetti A, Zuliani G, Romano F, et al. The Associazione Medica Sabin. Vitamin E and lipid peroxide plasma levels predict the risk of cardiovascular events in a group of healthy very old people.
J Am Geriatr Soc
2001
;
49
:
533
-7.
11
Halliwell B, Gutteridge JMC. Free radicals in biology and medicine. Oxford: Clarendon Press; 1999.
12
Voziyan PA, Metz TO, Baynes JW, Hudson BG. A post-Amadori inhibitor pyridoxamine also inhibits chemical modification of proteins by scavenging carbonyl intermediates of carbohydrate and lipid degradation.
J Biol Chem
2002
;
277
:
3397
-403.
13
Masters CL, Simms G, Weinman NA, Multhaup G, McDonald BL, Beyreuther K. Amyloid plaque core protein in Alzheimer disease and Down syndrome.
Proc Natl Acad Sci USA
1985
;
82
:
4245
-9.
14
Roberts LJ II, Montine TJ, Markesbery WR, et al. Formation of isoprostane-like compounds (neuroprostanes) in vivo from docosahexaenoic acid.
J Biol Chem
1998
;
273
:
13605
-12.
15
Hecht SS, McIntee EJ, Wang M. New DNA adducts of crotonaldehyde and acetaldehyde.
Toxicology
2001
;
166
:
31
-6.
16
Miyata T, Oda O, Inagi R, et al. β2-Microglobulin modified with advanced glycation end products is a major component of hemodialysis-associated amyloidosis.
J Clin Invest
1993
;
92
:
1243
-52.
17
McCance DR, Dyer DG, Dunn JA, et al. Maillard reaction products and their relation to complications in insulin-dependent diabetes mellitus.
J Clin Invest
1993
;
91
:
2470
-8.
18
Halliwell B, Chirico S. Lipid peroxidation: its mechanism, measurement, and significance.
Am J Clin Nutr
1993
;
57 Suppl 5
:
715S-24S.
19
Young IS, Trimble ER. Measurement of malondialdehyde in plasma by high performance liquid chromatography with fluorimetric detection.
Ann Clin Biochem
1991
;
28
:
504
-8.
20
Awad JA, Morrow JD, Takahashi K, Roberts LJ II. Identification of non-cyclooxygenase-derived prostanoid (F2-isoprostane) metabolites in human urine and plasma.
J Biol Chem
1993
;
268
:
4161
-9.
21
Voutilainen S, Morrow JD, Roberts LJ II, et al. Enhanced in vivo lipid peroxidation at elevated plasma total homocysteine levels.
Arterioscler Thromb Vasc Biol
1999
;
19
:
1263
-6.
22
Morrow JD, Roberts LJ II. Mass spectrometry of prostanoids: F2-isoprostanes produced by non-cyclooxygenase free radical-catalyzed mechanism.
Methods Enzymol
1994
;
233
:
163
-74.
23
Shimasaki H. Assay of fluorescent lipid peroxidation products.
Methods Enzymol
1994
;
233
:
338
-46.
24
Rosner B. Fundamentals of biostatistics. Pacific Grove (CA): Duxbury Press; 1999.
25
Kontush A, Beisiegel U. Measurement of oxidizability of blood plasma.
Methods Enzymol
1999
;
299
:
35
-49.
26
Pischon T, Hotamisligil GS, Rimm EB. Adiponectin: stability in plasma over 36 hours and within-person variation over 1 year.
Clin Chem
2003
;
49
:
650
-2.
27
Kurtz AJ, Lloyd RS. 1,N2-deoxyguanosine adducts of acrolein, crotonaldehyde, and trans-4-hydroxynonenal cross-link to peptides via Schiff base linkage.
J Biol Chem
2003
;
278
:
5970
-6.